Made in Germany seal
  1. Home / 
  2. Products / 
  3. Fire safety / 
  4. SHEV / 
  5. Continuous Rooflight S SHEV

Durable.
Tested.
Protective.

Fire safety

  • Certified smoke and heat exhaust device in accordance with DIN EN 12101-2
  • Rapid opening in the event of a fire for efficient smoke extraction
  • An important measure for preventive fire protection
Multiple opened LAMILUX Continuous Rooflight S​ RWA installed on an industrial flat roof in gable roof design

Safety

  • Resilience under high wind loads
  • Stability even when open
  • Durable and robust materials
Opened LAMILUX Continuous Rooflight S​ RWA in gable roof design with opened flaps and visible supporting structure

Diversity

  • Custom damper combinations for smoke and heat exhaust (SHEV) ratings according to customer requirements
  • Integration as single and double dampers
  • Actuation methods ranging from thermal activation to CO₂ and remotely electrically activated
Closed LAMILUX Continuous Rooflight S​ RWA installed on an industrial flat roof in gable roof design with continuous glazing

Variants of the Continuous Rooflight S SHEV

LAMILUX S continuous rooflight SHEV with single flap shown in technical cross-section

Single flap

LAMILUX RWA combination flap

Combination damper for ventilation and smoke exhaust

LAMILUX S continuous rooflight SHEV with opposing double flap shown in technical cross-section

Opposite double flaps

LAMILUX S continuous rooflight SHEV with double flaps arranged side by side shown in technical cross-section

Double flaps side by side

Dimensions and specifications of the Continuous Rooflight S Smoke Lift

SE30 Smoke Lift continuous rooflight, single flap (30° inclination of the glazed surfaces)

Type

top roof edge side Dimension
Dimension
x
Dimension
y
Ageo opening
area
Aerodynamically effective
opening area
100100530.53 m²0.32 m²
100*120530.63 m²0.38 m²
150100820.82 m²0.49 m²
150*120820.97 m²0.58 m²
2001001111.11 m²0.64 m²
200*1201111.31 m²0.76 m²
2501001401.40 m²0.80 m²
250*1201401.65 m²0.92 m²
3001001691.69 m²0.95 m²
300*1201691.99 m²1.09 m²

*Only in combination with PC 32 5-pane glazing

Smoke Lift Continuous Rooflight S (45° inclination of the glazed surfaces)

Type

top roof edge side Dimension
Dimension
x
Dimension
y
Ageo opening
area
Aerodynamically effective
opening area
80100530.53 m²0.33 m²
80*120530.63 m²0.38 m²
120100820.82 m²0.51 m²
120*120820.97 m²0.58 m²
1601001111.11 m²0.67 m²
160*1201111.31 m²0.77 m²
2001001401.40 m²0.80 m²
200*1201401.65 m²0.94 m²
2401001691.69 m²0.96 m²
240*1201691.99 m²1.12 m²

*Only in combination with PC 32 5-pane glazing

Smoke Lift Continuous Rooflight S (30° inclination of the glazed surfaces)

Type

top roof edge side Dimension
Dimension
x
Dimension
y
Ageo opening
area
Aerodynamically effective
opening area
100100531.02 m²0.64 m²
100*120531.20 m²0.75 m²
100200532.09 m²1.27 m²
100 TS**420534.24 m²2.42 m²
150100821.52 m²0.96 m²
150*120851.79 m²1.11 m²
150200823.12 m²1.90 m²
150 TS**420826.32 m²3.48 m²
2001001112.02 m²1.25 m²
200*1201112.38 m²1.48 m²
2002001114.14 m²2.57 m²
200 TS**4201118.40 m²4.96 m²
2501001402.52 m²1.54 m²
250*1201402.97 m²1.84 m²
2502001405.17 m²3.21 m²
250 TS**42014010.48 m²6.50 m²
3001001693.02 m²1.84 m²
300*1201693.56 m²2.21 m²
3002101696.21 m²3.85 m²
300*2401697.31 m²4.53 m²

* Only in combination with PC 32 glazing (5-pane)
** tandem-serial RWG

Smoke Lift Continuous Rooflight S double-flap (45° inclination of the glazed surfaces)

Type

top roof edge side Dimension
Dimension
x
Dimension
y
Ageo opening
area
Aerodynamically effective
opening area
120100821.22 m²0.94 m²
120*120821.43 m²1.09 m²
120200822.49 m²1.84 m²
120 TS**420825.05 m²3.54 m²
1601001111.63 m²1.25 m²
160*1201111.92 m²1.46 m²
1602001113.33 m²2.47 m²
160 TS**4201116.76 m²4.39 m²
2001001402.04 m²1.51 m²
200*1201402.40 m²1.68 m²
2002001404.17 m²2.71 m²
200 TS**4201408.47 m²5.08 m²
2401001692.45 m²1.71 m²
240*1201692.89 m²1.90 m²
2402101695.03 m²3.02 m²
240*2401695.92 m²3.49 m²

* Only in combination with PC 32 5-pane
glazing** tandem-serial RWG

Smoke Lift Continuous Rooflight S​E-SHED60 single flap (on the 60° north light side)

Type

top roof edge side Dimension
Dimension
x
Dimension
y
Ageo opening
area
Aerodynamically effective
opening area
110100530.53 m²0.32 m²
110*120530.63 m²0.37 m²
170100820.82 m²0.49 m²
170*120820.97 m²0.57 m²
2301001111.11 m²0.65 m²
230*1201111.31 m²0.76 m²
2901001401.40 m²0.81 m²
290*1201401.65 m²0.94 m²
3501001691.69 m²0.96 m²
350*1201691.99 m²1.12 m²

*Only in combination with PC 32 5-pane glazing

Closed LAMILUX Continuous Rooflight S​ RWA installed on an industrial flat roof in gable roof design with transparent glazing

Maximum security for large projects

The LAMILUX Smoke Lift Continuous Rooflight S is the ideal solution for industrial, sports, and warehouse facilities subject to strict fire safety regulations. The smoke and heat exhaust dampers are integrated directly into the gable roof Continuous Rooflight and open automatically in the event of a fire to quickly vent smoke and toxic gases to the outside. This keeps escape and rescue routes clear and ensures the safety of people and buildings.

In addition to its fire safety function, the system offers added value in everyday use: The dampers can also be used for natural ventilation, providing fresh air, a comfortable indoor climate, and energy savings. Robustly constructed and tested in accordance with EN 12101-2, the Smoke Lift Continuous Rooflight S combines reliable safety with practical convenience for modern industrial buildings.

Learn more about the Continuous Rooflight S

EN 12101-2

Reliable Smoke and Heat Exhaust

The LAMILUX Smoke Lift Continuous Rooflight S has been tested and certified in accordance with European standards. These specifications guarantee operational safety in snow, wind, fire, and sub-freezing temperatures.

Smoke Lift Continuous Rooflight S

With the Smoke Lift Continuous Rooflight S, building designers and architects of industrial and warehouse facilities rely on a system that combines reliable smoke and heat exhaust with an additional ventilation function. Integrated directly into the roof, it meets the highest safety standards according to EN 12101-2 while also ensuring a healthy indoor climate.

Documents and downloads

Skylights

Product brochure

en-us-gb

Smoke and heat exhaust systems

Brochure

en-us-gb