Energy efficiency seal
  1. Home / 
  2. Products / 
  3. Continuous rooflight / 
  4. Continuous rooflight with photovoltaic panels

Power-generating.
Environmentally conscious.
Reliable.

Energy efficiency

  • Combination of natural light and active electricity generation via photovoltaics
  • Maximum energy efficiency thanks to a thermally separated design
  • Plastic glazing with low U-values down to 1.2 W/(m²K)
  • Energy-efficient natural ventilation
LAMILUX Continuous Rooflight S​ energyline installed on a flat roof with inclined glazing

Security

  • Linear fire barrier to prevent the spread of fire
  • Easy integration of smoke and heat exhaust systems
  • Flexibly combinable damper systems for maximum smoke exhaust areas
  • Secure mounting of the glazing thanks to dynamic torque control
LAMILUX Continuous Rooflight S​ energyline installed on a flat roof with inclined integrated solar modules for combined daylight use and energy generation

Stability

  • First Continuous Rooflight with tested watertightness under heavy rain and storm conditions (DRI 3.0 m²/s)
  • Innovative system components designed to withstand wind and snow loads
  • Bionic Dynamic Tensioning Technology for flexible force-stress compensation
  • Absorption of differences in expansion
LAMILUX Continuous Rooflight S​ energyline installed on a flat roof in gable design with integrated solar modules on both sides

Application

  • Ideal for industrial buildings and production facilities
  • Efficient assembly and maintenance by LAMILUX
  • Optimal use of daylight for lighting and energy generation
  • Flexible sizes for new construction and renovation
LAMILUX Continuous Rooflight S​ energyline with photovoltaic system installed on a flat roof with integrated solar modules for combined daylight and energy generation

Design

  • Architecturally striking structure designed as a "Northern Lights" shed
  • Wide range of glazing options
  • Custom-fit design for a wide variety of construction projects
  • Custom color options based on the RAL color chart
LAMILUX Continuous Rooflight S​ energyline installed on a flat roof in gable design with integrated solar modules

Glazing options for the S energyline continuous rooflight

LAMILUX Continuous Rooflight S​ with PC10 glazing option shown in technical cross-section

Standard glazing PC10

  • U-value: 2.5 W/(m²K)
  • Sound insulation value: 17 dB
  • Fire rating: B-s1, d0
  • Light transmission: approx. 61%
LAMILUX Continuous Rooflight S​ with glazing options PC10 and PC6 shown in technical cross-section

Standard glazing: PC 10 + PC 6

  • U-value: 1.8 W/(m²K)
  • Sound insulation value: 18 dB
  • Fire rating: B-s1, d0
  • Light transmission: approx. 44%
LAMILUX Continuous Rooflight S​ with glazing options PC10, PC6 and thermal shown in technical cross-section

Energy-efficient glazing:
PC 10 + PC 6 + thermal composite 16

  • U-value: 1.4 W/(m²K)
  • Sound insulation value: 17 dB
  • Fire rating: B-s1, d0
  • Light transmission: approx. 44%
LAMILUX S continuous rooflight with PC32 glazing option shown in technical cross-section

PC 32

energy-efficient glazing

  • U-value: 1.2 W/(m²K)
  • Sound insulation value: 18 dB
  • Building material class: E, d0
  • Light transmission: approx. 32%
LAMILUX Continuous Rooflight S​ with sound 16 glazing option shown in technical cross-section

Soundproof glazing 16 mm 31

dB

  • U-value: 2.3 W/(m²K)
  • Sound insulation value: 31 dB
  • Building material class: E, d0
  • Light transmission: approx. 54%
LAMILUX S continuous rooflight with PC32 glazing option shown in technical cross-section

Chemical-resistant glazing,
GRP composite, 32 mm

  • U-value: 1.3 W/(m²K)
  • Sound insulation value: 17 dB
  • Building material class: E, d0
  • Light transmission: approx. 26%

Photovoltaic performance in the Continuous Rooflight S energyline

Top roof edge side width (in m) / Top roof edge side length (in m)      
 61015202530
1 1.50 kWp2.25 kWp3.00 kWp3.75 kWp4.50 kWp
1.751.50 kWp2.50 kWp3.75 kWp5.00 kWp6.25 kWp 
2.2 3.00 kWp4.50 kWp6.00 kWp7.50 kWp9.00 kWp
3.4 4.50 kWp6.75 kWp9.00 kWp11.25 kWp13.50 kWp
3.73.00 kWp5.00 kWp7.50 kWp10.00 kWp12.50 kWp 

- Custom sizing and power calculation are performed on a project-by-project basis

LAMILUX Continuous Rooflight S​ energyline installed on a flat roof

Double the efficiency for more sustainable buildings

The LAMILUX Continuous Rooflight S combines daylighting technology with active power generation. Designed as a shed roof, it combines high-quality daylight from the north-facing glazing with photovoltaic-equipped, light-impermeable modules on the south side at the optimal incidence angle of 30°/60°. As a result, the system not only provides abundant, diffused light inside the building but also generates electricity and permanently reduces energy costs. The thermally separated construction and robust design, engineered to withstand wind and snow loads, make the Continuous Rooflight S a smart, future-proof solution for modern industrial and administrative buildings. Thanks in particular to its integration of photovoltaics and flexible sizing options, the Continuous Rooflight S is ideally suited for renovation projects.

Learn more about flat roof renovations with LAMILUX!

Technical details of the Continuous Rooflight S

Bionic Dynamic Clamping Technology (BDS)
LAMILUX continuous rooflight with bionic dynamic tension technology shown in technical cross-section

Effect: In zones consisting of multiple materials in a hybrid construction, the ridge contains rigid, elastic, and semi-elastic regions. In addition to clamping connections and static interlocking, the components are also connected to one another, for example, by friction locks. This results in a structure that is both elastic and consistently form-locked.

Benefit: Under vertical and horizontal compressive and tensile loads, the system prevents both excessive drifting apart and compression of the components, ensuring they remain connected within defined movement and displacement tolerances. Even under heavy wind and snow loads, the skylight system remains torsionally rigid and thus airtight and secure.

  • Flexible Force and Stress Compensation
  • Form-fit connection of the ridge area consisting of elastic, rigid, and semi-elastic zones
  • Bionic design principle through integrated form and function
  • Skylight system withstands very heavy wind and snow loads
Active Expansion Absorber (ADA)
LAMILUX Continuous Rooflight B with Active Expansion Absorber shown in technical cross-section

Function: The Active Expansion Absorber compensates for the stresses and strains generated under load. To achieve this, the seals are connected to the cover strips along their entire length in a shear-resistant manner.
Benefits:

  • Optimal protection of the structure against snow, ice, wind, and intense heat generation
  • Cover strips feature integrated guide rails for mounting hardware, sunshades, and maintenance equipment
  • Clamping security is enhanced by an expanded contact area
Isothermal Load Converter (ITL)
LAMILUX continuous rooflight with isothermal load converter shown in technical cross-section

Function: The Isothermal Load Converter (ITL) specifically leads the load from the Continuous Rooflight to its substructure. Since this relieves the base profile of loads and stresses, metal materials are no longer required, and high-quality plastic with excellent heat insulation values can be used for the base profile.
Benefits: With ITL technology, we guarantee optimized temperature profiles and thus a low risk of condensation on the base profile of the Continuous Rooflight.

  • Outstanding Uf values in the base profile and even better thermal insulation
  • Increased load-bearing capacity of the base profile
  • Significantly reduced risk of condensation
  • Optimized ventilation at the seam base
  • Smooth interior surface with fewer edges for reduced dirt accumulation
  • Torsionally rigid box-section profile
Dampers for SHEV and ventilation systems
Flap system for SHEV and ventilation including photovoltaic system
  • Integration as a single flap on the Nordlicht side
  • Opening and closing: manual or automated
  • Smoke Lift Continuous Rooflight S as a single damper in accordance with DIN EN 12101-2
  • Electric motors (24 V/230 V) with sliding shaft drives or pneumatic drive units with pneumatic cylinders
  • Energy-efficient control of the damper systems for natural ventilation with a wind and rain sensor set as well as additional control components
  • Optimal water tightness under driving rain thanks to a welded sealing frame
  • Optimal insulation performance
  • High safety during assembly of the Continuous Rooflight, as separate welding of sealing points is not required
  • Guaranteed airtight sealing of the louver system through compensation for manufacturing tolerances by the balloon seal

Top roof edge side dimension (in cm)Dimension x (in cm)Dimension y (in cm)Ageo opening area (in m²)Aerodynamically effective opening area (in m²)
100100530.530.32
100*120530.630.38
150100820.820.49
150*120820.970.58
2001001111.110.64
2001201111.310.76
2501001401.400.80
250*1201401.650.92
3001001691.690.95
300*1201691.991.09

Linear Breakthrough Protection (LDS)
A profile of the LDSLAMILUX continuous rooflight with linear fire protection barrier under fire exposure shown in technical detailLAMILUX continuous rooflight with linear fire protection barrier after fire exposure shown in technical detail

Effect: When attached to a substructure, such as a window frame, the roof membrane is usually pulled upward to the upstand and led under the base profile of the Continuous Rooflight. It often happens that, during a fire inside the building, the roof membrane on the inside of the upstand ignites and tends to burn toward the outside of the roof like a “fuse.”
Linear Fire Protection (LDS) is an intelligent system designed to limit the spread of fire in the area of the roof penetration. The Continuous Rooflight profile plays an essential role in this: It is made of a thermoplastic plastic that softens at high temperatures on the upstand and lies directly over the burning edge of the roofing membrane. This seals the burning joints, cuts off the oxygen supply, and extinguishes the flames at that point.
Benefits: The LDS prevents flames from spreading to the roof. Despite softening due to high temperatures, the base profile remains stable during a fire because it is cooled and reinforced by the metal profile of the glazing bead.

  • Prevents the spread of fire on the roof in the area of roof penetrations in accordance with the provisions of DIN 18232-4
  • Eliminates the need for heavy gravel fill around the Continuous Rooflight
  • Patented technology
Energy efficiency
LAMILUX Continuous Rooflight B with energy-efficient base profile shown in thermal simulation modelEnergy-optimized profile in the thermal simulation modelEnergy-efficient design shown in thermal simulation modelEnergy efficiency in the thermal simulation modelEnergy efficiency in the thermal simulation model

Optimized Isotherm Curves

With the LAMILUX Continuous Rooflight S, the 10°C isotherm runs consistently throughout the structure. Our guarantee: a significantly reduced risk of condensation on the interior surfaces of the structure.

The comprehensive thermal insulation technology incorporated throughout the entire structure ensures the best U-values of any Continuous Rooflight system approved throughout Europe. The energy efficiency properties have been tested, thereby documenting the uniform insulation performance across the profiles of the Continuous Rooflight system.

Possible building connections for the Continuous Rooflight S energyline

LAMILUX Continuous Rooflight B construction detail with timber connection detail

Assembly on glulam beams

LAMILUX Continuous Rooflight B construction detail with steel connection detail

Assembly on a sheet steel frame

made from high-quality steel grades such as S 280 GD + Z 275 or S 320 GD + Z 275

LAMILUX Continuous Rooflight B construction detail with concrete connection detail

Assembly on a concrete upstand

Accessories for the LAMILUX Continuous Rooflight S

LAMILUX Continuous Rooflight S​ energyline with photovoltaic system and fall-through grille for fall protection

Permanently fall-through protected as certified by the BG, suitable for clear widths from 1.00 to 4.00 m, and can be flexibly mounted on curved sheet metal

LAMILUX Continuous Rooflight S​ energyline with integrated sun protection to reduce light and heat gain

Perforated sheet metal available in any RAL color: permanently fall-through protected and providing reliable protection against hail and UV radiation

LAMILUX Continuous Rooflight S​ energyline with gable fan for active ventilation

All fans are equipped with an electrically operated shutter; installation depends on the width of the skylight, the installation orientation, and the inclination of the ridge cap.

LAMILUX Continuous Rooflight S​ energyline with accessory for hard roofing in roof construction

The glazing meets the requirements for hard roofing (Broof(t1)) and can optionally be designed as a fusible surface

LAMILUX Continuous Rooflight S​ energyline with safety stripe for enhanced visibility and safety

Integrated safety zone in the lower glazing area with a discreet design for permanent fall-through proofing

LAMILUX Continuous Rooflight S​ energyline with smoke barrier for controlled smoke extraction in case of fire

Smoke-tight and non-flammable (A1), it consists of a structure made of 2 mm aluminum / PC 10 / 2 mm aluminum and is used to divide smoke compartments; when smoke enters, the PC in the skylight glazing melts, and the partition continues to contain the area.

LAMILUX Continuous Rooflight S​ energyline with insect screen as ventilation accessory

Integration into the flap systems to protect against insects when the flaps are open

Fall protection grille
LAMILUX Continuous Rooflight S​ energyline with photovoltaic system and fall-through grille for fall protection

Permanently fall-through protected as certified by the BG, suitable for clear widths from 1.00 to 4.00 m, and can be flexibly mounted on curved sheet metal

Sun protection
LAMILUX Continuous Rooflight S​ energyline with integrated sun protection to reduce light and heat gain

Perforated sheet metal available in any RAL color: permanently fall-through protected and providing reliable protection against hail and UV radiation

Gable wall fan
LAMILUX Continuous Rooflight S​ energyline with gable fan for active ventilation

All fans are equipped with an electrically operated shutter; installation depends on the width of the skylight, the installation orientation, and the inclination of the ridge cap.

"Hard roofing"
LAMILUX Continuous Rooflight S​ energyline with accessory for hard roofing in roof construction

The glazing meets the requirements for hard roofing (Broof(t1)) and can optionally be designed as a fusible surface

LAMILUX Safety Stripe
LAMILUX Continuous Rooflight S​ energyline with safety stripe for enhanced visibility and safety

Integrated safety zone in the lower glazing area with a discreet design for permanent fall-through proofing

Smoke compartmentalization
LAMILUX Continuous Rooflight S​ energyline with smoke barrier for controlled smoke extraction in case of fire

Smoke-tight and non-flammable (A1), it consists of a structure made of 2 mm aluminum / PC 10 / 2 mm aluminum and is used to divide smoke compartments; when smoke enters, the PC in the skylight glazing melts, and the partition continues to contain the area.

Insect protection grid
LAMILUX Continuous Rooflight S​ energyline with insect screen as ventilation accessory

Integration into the flap systems to protect against insects when the flaps are open

Continuous Rooflight S for energy-efficient daylight

The LAMILUX Continuous Rooflight S combines optimal natural lighting with integrated photovoltaics. It brings uniform, natural light into the building while simultaneously generating green electricity, thereby reducing energy consumption and operating costs. With proven stability, thermal insulation, and durability, it is the ideal solution for a more sustainable architecture of the future.

Documents and downloads

Intended use of daylight systems

Instructions for use

cz, dk, en-us-gb, es, fi, fr, gb, hu, it, nl, no, pl, ro, se, tr

LAMILUX Building Control Systems

Brochure

en-us-gb

Skylights

Product brochure

en-us-gb