LAMILUX fire-resistant window designed as a linear rooflight with fire-resistant glazing

Fire-rated windows

  1. Home / 
  2. Products / 
  3. Fire safety / 
  4. Fire-rated windows

Preventive fire protection with LAMILUX fire-rated windows

When it comes to preventive fire protection, our LAMILUX fire-rated windows play a key role: They reliably seal off roof openings in the event of a fire and prevent the fire from spreading to adjacent areas of the building. With certified fire resistance ratings, even under additional loads, and a high degree of design flexibility, these windows can be safely and aesthetically integrated into a wide variety of building concepts, ideal for escape routes, fire compartments, and sophisticated architecture that incorporates natural light.

Multiple LAMILUX fire-resistant windows installed in a row on a gravel flat roof

Fire-resistant windows withstand fire and heat

A fire-rated window is a window that, in the event of a fire, withstands fire and heat for a certain period of time; the higher the performance class, the longer the duration and the greater the heat resistance. During this time, the component must ensure room sealing, support its own weight and any additional loads, and limit heat transfer. Fire-rated windows achieve this protection through special layers in the glass panes and materials, as well as design details of the frame and load-bearing profiles. This prevents the spread of fire to other sections of the building for up to 90 minutes.

Configure fire-rated windows!

DIN EN 13501-2

Regarding the REI Fire Resistance Class

The EN 13501-2 standard classifies the fire resistance of building components based on three key criteria: bearing capacity (R), room sealing (E), and thermal insulation (I). For each of these criteria, the duration of performance is specified in minutes depending on the tested protective effect of the building element. Common time ratings are: 15, 20, 30, 45, 60, 90, 120, 180, and 240 minutes.

DIN 4102-2

To indicate fire resistance class F

The fire resistance class according to DIN 4102-2 is indicated by the letters F or G followed by a number. This number represents the tested fire resistance duration in minutes, with the result rounded to the nearest value divisible by 30. This results in the standard classifications F30, F60, F90, or G30, G60, and G90.

Benefits of window fire resistance

Multiple LAMILUX fire-resistant windows installed on a gravel flat roof in different configurations

A wide variety of products meeting high quality standards

Detail view of a LAMILUX fire-resistant window showing screwed frame profiles and fire-resistant glazing installed on a flat roof

Optimized sealing and drainage system

LAMILUX fire-resistant window designed as a continuous rooflight with fire-resistant glazing in a corridor or atrium area between brick wall and interior space

Active energy management

Detail view of multiple LAMILUX fire-resistant windows

Tested fire resistance and functional integrity in accordance with EN 13501-2

A comparison of LAMILUX fire-rated windows

A comparison of LAMILUX fire-rated windows
Design
Sizes
Safety
Assembly
Application
Variants
Product presentation of the LAMILUX flat roof window fire resistance

Glass skylight

Flat roof, monopitched roof

Sizes up to 2.5 m x 2 m

Protection against forced entry for REI 30 RC3

Factory-assembled unit mounted on a steel frame

Up to a 15° roof inclination; with a concrete substructure

REI 30, item no.: Z-19.141-2723

REI 60, item no.: Z-19.141-2724

REI 90, item no.: Z-19.141-2725

Fire-resistant glass roof with multi-part glazing and robust metal construction

Glass roof

Flat roof, monopitched roof, gable roof

Can be customized to fit on site conditions

Protection against forced entry for REI 30 RC3

On-site assembly due to a longer design period

For roof inclinations from 2° to 80° on a concrete substructure; wood is also suitable for REI 30.

REI 30

REI 60

Opened LAMILUX fire-resistant windows with fire-resistant glazing installed on a flat roof

Fire safety with skylights

In addition to preventive fire protection, smoke and heat exhaust systems are also a key component of an effective fire protection strategy. While fire-rated windows prevent the spread of fire, SHEV systems ensure that, in the event of a fire, smoke and heat are quickly and controlledly vented to the outside. This keeps escape and rescue routes accessible and maintains visibility for emergency responders. To take a holistic approach to fire protection, both components are therefore necessary to protect lives, buildings, and property in an emergency.

Discover our SHEV solutions  

FAQ

What is considered preventive fire safety?

Preventive fire protection encompasses all structural, technical, and organizational measures taken during the planning and construction phases to minimize damage in the event of a fire. The goal is to prevent the spread of fire and smoke, keep escape routes clear, and protect people and property. These include, for example, fire-resistant building components, fire-rated glazing, smoke and heat exhaust systems (SHEV), and clear evacuation plans.

When is a fire-rated window required?

A fire-rated window is always required when it is necessary to prevent the spread of fire or smoke across a roof opening into other fire compartments. This is the case, for example, in stairwells, hallways, escape routes, or between different occupancy units. Fire-rated windows with a certified fire resistance rating provide secure room sealing to the upper levels even while allowing natural light to enter.

Where must fire-rated windows be installed?

Fire-rated windows are used wherever legal regulations or fire safety plans require a fire-resistant barrier, particularly in roof areas above escape and rescue routes, above fire walls, or in areas where fire compartments meet. They are frequently used in public buildings, special-purpose structures, industrial facilities, or stairwells and must meet a defined fire resistance rating in accordance with state building codes.