Passivhaus Institute certified component, phC, cool temperate climate
  1. Home / 
  2. Products / 
  3. Passivhaus / 
  4. Glass skylight for Passivhaus

Energy-efficient.
Weather-resistant.
Stylish.

Energy efficiency

  • First Passivhaus window certified in efficiency class phC
  • The window has an outstanding U-value of 0.85 W/(m²K)
  • Uninterrupted isotherm curve in the frame profile to prevent thermal bridges
  • Comprehensive Environmental Product Declaration for optimized life cycle assessments
Detailed view of the LAMILUX Glass Skylight FE Passivhaus in the interior with sky view

Design

  • High-Quality Design Honored with the 2025 German Design Award
  • Enhanced aesthetics for modern, energy-efficient architectural concepts
  • Prevents dirt marks thanks to a flush water drainage system
  • Customization through a wide range of RAL colors
LAMILUX Glass Skylight FE Passivhaus in interior space, square daylight opening with insulated light well

Application

  • Ideal for construction projects with the highest energy efficiency requirements
  • Versatile applications ranging from residential construction to public buildings
  • Ideal for both cold and warm regions, providing effective thermal insulation
  • Compatible with standard planning processes thanks to BIM-ready data
LAMILUX Glass Skylight FE Passivhaus arranged in a row on flat roof with gravel

Comfort

  • Natural ventilation for a comfortable indoor climate
  • Glazing with high sound insulation for a quieter interior
  • Available with either thermal insulation or sun protection insulating glass
  • Daylighting element and upstand pre-assembled at the factory for quick installation
LAMILUX Glass Skylight FE Passivhaus glazing detail with sky reflection

Safety

  • Reliable fall-through proofing in accordance with DIN EN 18008-6
  • Fire protection thanks to smoke exhaust systems in accordance with DIN EN 12101-2 and fire resistance in accordance with DIN EN 13501-5
  • High resistance to wind loads in accordance with DIN EN 12211, Class C5
  • Optimal water tightness under driving rain, Class E 1950, and air permeability, Class 4 
LAMILUX Glass Skylight FE Passivhaus arranged in rows

Glazing options for the Glass Skylight FE Passivhaus

LAMILUX Glass Skylight FE Passivhaus with quadruple thermal insulation glazing in technical cross-section

4-Pane thermal insulation glazing (TSG – TSG – TSG – laminated safety glass inside)

  • Ug value: approx. 0.48 W/(m²K)
  • Sound insulation value: approx. 39 dB
  • Light transmission: approx. 65%
  • Energy transmittance: approx. 48%
LAMILUX Glass Skylight FE Passivhaus with thermal insulation glazing shown in technical cross-section

Thermal insulation glazing with a matt light foil (MHF), 4-pane (TSG – TSG – TSG – laminated safety glass inside)

  • Ug value: approx. 0.48 W/(m²K)
  • Sound insulation value: approx. 39 dB
  • Light transmission: approx. 33%
  • Energy transmittance: approx. 46%
LAMILUX Glass Skylight FE Passivhaus with quadruple glazing in technical cross-section

Sun protection insulating glass, 4-pane (TSG – TSG – TSG – laminated safety glass inside), 60/30

  • Ug value: approx. 0.46 W/(m²K)
  • Sound insulation value: approx. 39 dB
  • Light transmission: approx. 49%
  • Energy transmittance: approx. 29%
LAMILUX Glass Skylight FE Passivhaus with 60/30 MHF solar control glazing shown in technical cross-section

Sun protection insulating glass with a matt light foil (MHF), 4-pane (TSG – TSG – TSG – laminated safety glass inside), 60/30

  • Ug value: approx. 0.46 W/(m²K)
  • Sound insulation value: approx. 39 dB
  • Light transmission: approx. 25%
  • Energy transmittance: approx. 27%
LAMILUX Glass Skylight FE Passivhaus with quadruple solar control glazing in technical cross-section

Sun protection insulating glass, 4-pane (TSG – TSG – TSG – laminated safety glass inside), 50/25

  • Ug value: approx. 0.46 W/(m²K)
  • Sound insulation value: approx. 39 dB
  • Light transmission: approx. 41%
  • Energy transmittance: approx. 23%
LAMILUX Glass Skylight FE Passivhaus with solar control glazing shown in technical cross-section

Sun protection insulating glass with a matt light foil (MHF), 4-pane (TSG – TSG – TSG – laminated safety glass inside), 50/25

  • Ug value: approx. 0.46 W/(m²K)
  • Sound insulation value: approx. 39 dB
  • Light transmission: approx. 21%
  • Energy transmittance: approx. 22%
LAMILUX Glass Skylight FE Passivhaus with multiple glazing in technical cross-section

Sun protection insulating glass, 4-pane (TSG – TSG – TSG – laminated safety glass inside), 70/37

  • Ug value: approx. 0.46 W/(m²K)
  • Sound insulation value: approx. 39 dB
  • Light transmission: approx. 56%
  • Energy transmittance: approx. 32%
LAMILUX Glass Skylight FE Passivhaus with quadruple glazing in technical cross-section

Sun protection insulating glass with a matt light foil (MHF), 4-pane (TSG – TSG – TSG – laminated safety glass inside), 70/37

  • Ug value: approx. 0.46 W/(m²K)
  • Sound insulation value: approx. 39 dB
  • Light transmission: approx. 28%
  • Energy transmittance: approx. 30%

Available sizes of the Glass Skylight FE Passivhaus

Order Dimensions top roof edge side (in cm) 
80 / 80100 / 100120 / 120
90 / 90100 / 150150 / 150
90 / 120100 / 200180 / 180

Multiple LAMILUX flat roof windows in grid arrangement, square daylight openings in wooden ceiling structure

Glass Skylight FE Passivhaus for greater energy efficiency

Sustainable construction plays a key role in climate protection, resource conservation, and ensuring the long-term viability of our buildings. This is precisely why energy-efficient building components are becoming increasingly important for making building operations more sustainable. Here, the LAMILUX Glass Skylight FE Passivhaus, the first certified Passivhaus window, makes a significant contribution: It meets the strict requirements of the certified Passivhaus efficiency class phC and impresses with an excellent U-value of 0.85 W/(m²K).
 

A complete system free of thermal bridges throughout, a kink-free isotherm curve, and a full environmental product declaration make this Passivhaus window the ideal solution for anyone building in an environmentally responsible manner without compromising on design, comfort, or performance.

Configure Glass Skylight FE Passivhaus!

Accessories for the Glass Skylight FE Passivhaus

LAMILUX flat roof window with concealed chain actuator as functional accessory
LAMILUX aluminium flat roof window with integrated sun protection for effective shading

Sun protection is available either as an internal system with safety pull cords, an exterior roller shade, or a rigid version with a leafy tree effect. A design with an integrated solar panel is also available as an option.

LAMILUX flat roof window with insect screen as practical accessory

 Can be optionally integrated into the upstand 

LAMILUX FE Passivhaus roof window with glare protection as functional accessory

Optional for all sizes: an electrically operated, internal sunshade that attaches to the inside of the upstand

LAMILUX aluminium flat roof window with reed contact as product extension for opening monitoring
LAMILUX FE Passivhaus roof window with concealed cable routing as functional accessory
Sun protection
LAMILUX aluminium flat roof window with integrated sun protection for effective shading

Sun protection is available either as an internal system with safety pull cords, an exterior roller shade, or a rigid version with a leafy tree effect. A design with an integrated solar panel is also available as an option.

Insect screen
LAMILUX flat roof window with insect screen as practical accessory

 Can be optionally integrated into the upstand 

Anti-glare
LAMILUX FE Passivhaus roof window with glare protection as functional accessory

Optional for all sizes: an electrically operated, internal sunshade that attaches to the inside of the upstand

DIN EN 12101-2

Smoke and Heat Exhaust via Natural Ventilation

This standard specifies the requirements for naturally operating smoke and heat exhaust devices (NRWG). The Glass Skylight FE Passivhaus is optionally available in a SHEV design, tested in accordance with DIN EN 12101-2 for greater safety in the event of a fire and controlled smoke extraction through the roof.

DIN EN 12211

Resistance to Wind Loads

This standard tests the stability of windows under wind loads. The LAMILUX Passivhaus window meets the high Class C5 standard and can therefore withstand even extreme wind loads, ideal for exposed locations and buildings at high elevations.

DIN EN 1027

Protection Against Driving Rain

The DIN EN 1027 standard evaluates the water tightness under driving rain of window and door units.
The Glass Skylight FE Passivhaus achieves excellent protection with Class E 1950. Even during heavy rain combined with high wind loads, the skylight remains reliably watertight.

Passivhaus quality at its best

With the Glass Skylight FE Passivhaus, LAMILUX offers a well-thought-out solution for anyone who wants to consistently implement sustainable construction. This certified Passivhaus window impresses with outstanding insulation values, a thermal bridge-free design, and maximum airtightness. Combined with high-quality materials, a cohesive design, and a complete environmental product declaration, it meets the highest architectural and ecological standards.

Documents and downloads

Glass Skylight FE Passivhaus

Passivhaus certificate

en-us-gb

Glass Skylight FE Passivhaus

BIM Download

cz, en-us-gb, fr, nl, pl, ru

Glass skylight

Brochure

en-us-gb

Intended use of daylight systems

Instructions for use

cz, dk, en-us-gb, es, fi, fr, gb, hu, it, nl, no, pl, ro, se, tr

LAMILUX Passivhaus Daylight Systems

Brochure

en-us-gb

Skylights

Product brochure

en-us-gb