Energy efficiency

  • First Continuous Rooflight system certified to the Passivhaus standard
  • Classified according to Passivhaus efficiency class phB
  • Optimized U-values of 0.95 W/(m²/K)
  • Thermal bridge-free system with a continuous isothermal curve
LAMILUX Continuous Rooflight B Passivhaus installed on a flat roof of an industrial building

Stability

  • First Continuous Rooflight with certified watertightness under heavy rain and storm conditions (DRI 3.0 m²/s)
  • Design snow load up to 4.4 kN/m² according to Eurocode
  • Hail resistance class HW5 due to GFUP glazing
  • Maximum stability of the hinged systems, even when open
LAMILUX Continuous Rooflight B Passivhaus installed on a large flat roof with curved glazing

Security

  • Proven fire resistance and hard roofing Broof(t1)
  • Tested melt-through resistance of the glazing in accordance with DIN 18230-1
  • Fall-through proofing during installation and as a permanent solution
  • European Technical Approval (ETA) and General Inspectorate Approval (abZ)
Interior view of a LAMILUX Continuous Rooflight B Passivhaus with curved glazing and steel structure

Application

  • Ideal for demanding industrial, commercial, and special-purpose buildings
  • Enhanced energy efficiency for large industrial buildings
  • Efficient assembly and maintenance by LAMILUX
  • Ideal for new construction and renovation projects
LAMILUX Continuous Rooflight B Passivhaus installed on a flat roof with curved glazing for energy-efficient natural daylight

Design

  • Arched structure with architectural appeal
  • Modular system with coordinated individual components
  • Color options for steel sheet frames and aluminum profiles according to RAL
  • Sustainable design certified by environmental product declarations
Detail view of a LAMILUX Continuous Rooflight B Passivhaus with curved glazing and highly insulated construction installed on a flat roof

Frame specifications for the Passivhaus Continuous Rooflight B

Frame SpecificationsFrame width
bf
mm
Frame U-value
Uf
W/(m² K)
Glass edge Ψ-value
Ψg
W/(m K)
Temperature factor
fRsi=0.25
[-]
Top (to)821.65-0.0060.70
Page(s)1182.10-0.0010.70
Bottom(bo)821.65-0.0060.70
Post (m01)
Crossbar
600.810.0030.74
Post (m02)
Section glazing bar
380.880.0020.75
 Spacer: -Secondary seal: -   

Technical details of the LAMILUX Continuous Rooflight B Passivhaus

Dynamic Torque Control (DMR)
LAMILUX Continuous Rooflight B with Dynamic Torque Control shown in technical detail

Effect: A spring integrated into the mounting frame (DMR spring) below the glazing bead ensures that the glazing is supported with optimized stress distribution. This secures the glazing in place with a defined holding force, even under load.
Benefits: The glazing remains stress-optimized in all situations and is optimally secured, as the applied loads are optimally cushioned and absorbed by the mounting frame.

Protection against strong wind loads

  • High stability of the flaps even when open
  • Even better anchoring of the polycarbonate glazing
  • Additional protection for the sash systems through spring-mounted multi-jointed crossbars
Active Expansion Absorber (ADA)
LAMILUX Continuous Rooflight B with Active Expansion Absorber shown in technical cross-section

Function: The Active Strain Absorber compensates for the stresses and strains generated under load. To achieve this, the seals are continuously and shear-resistant connected to the cover strips.
Benefit: Optimal protection of the structure against snow, ice, wind, and intense heat generation.

Safety in Detail

  • The glazing is tightly and form-fit connected to the cover strips and supporting struts.
  • The cover strips feature integrated guide rails for mounting hardware, sunshades, and maintenance devices.
  • Clamping security is enhanced by an expanded contact area.
Linear Breakthrough Protection (LDS)
LAMILUX continuous rooflight with linear fire protection barrier shown in technical cross-section

Effect: When attached to a substructure, such as a window frame, the roof membrane is usually pulled upward to the upstand and led under the base profile of the Continuous Rooflight. It often happens that, during a fire inside the building, the roof membrane on the inside of the upstand ignites and tends to burn toward the outside of the roof like a “fuse.”
Linear fire protection should be understood as an intelligent system designed to limit the spread of fire in the area of the roof penetration. The Continuous Rooflight profile plays an essential role in this: It is made of a thermoplastic plastic that softens when exposed to fire at the upstand and lies directly over the burning edge of the roofing membrane. This seals the burning joints, cuts off the oxygen supply, and extinguishes the flames at that point.
Benefits: The LDS prevents flames from spreading to the roof. Despite softening due to high temperatures, the base profile remains stable during a fire because it is cooled and reinforced by the metal profile of the glazing bead.

LDS: sophisticated fire protection technology

  • The spread of fire on the roof in the area of roof penetrations is prevented in accordance with the provisions of DIN 18232-4. Further details can be found in our interactive planning guide.
  • Patented technology
  • Eliminates the need for heavy gravel fill around the Continuous Rooflight
Energy efficiency
LAMILUX Continuous Rooflight B with energy-efficient base profile shown in thermal simulation modelEnergy-optimized profile in the thermal simulation modelEnergy-efficient design shown in thermal simulation modelEnergy efficiency in the thermal simulation modelEnergy efficiency in the thermal simulation model

Optimized Isotherm Curves

With the LAMILUX Continuous Rooflight B, the 10°C isotherm runs consistently throughout the structure. Our guarantee: a significantly reduced risk of condensation on the interior surfaces of the structure.

The comprehensive thermal insulation technology throughout the entire structure ensures the best Uw values of any Continuous Rooflight system approved throughout Europe. The energy efficiency properties have been tested and verified in accordance with ETAG 010. This documents the uniform insulation performance across the profiles of the Continuous Rooflight system. A calculation of the Uw values is provided at no additional cost upon order and is confirmed with the quality certificate.

LAMILUX Continuous Rooflight B Passivhaus installed on a flat roof with closed glazing

Energy efficiency at the highest level

With the world’s first Passivhaus-certified Continuous Rooflight, LAMILUX is setting a new benchmark in daylight architecture. The independent certification not only confirms the system’s outstanding thermal insulation and energy efficiency but also makes the Continuous Rooflight B a crucial component of environmentally conscious building design.

In an era of increasing demands for climate protection and resource conservation, the LAMILUX Continuous Rooflight B offers a forward-looking solution: It significantly reduces heating and cooling costs, lowers a building’s energy consumption, and thus actively contributes to CO₂ savings. In this way, LAMILUX makes a valuable contribution to a style of construction that meets the needs not only of today’s generation but also of future generations.

Discover more Passivhaus-certified products!

Possible building connections for the Passivhaus Continuous Rooflight B

LAMILUX Continuous Rooflight B construction detail with timber connection detail

Assembly on glulam beams

LAMILUX Continuous Rooflight B construction detail with steel connection detail

Assembly on a sheet steel frame

made from high-quality steel grades such as S 280 GD + Z 275 or S 320 GD + Z 275

LAMILUX Continuous Rooflight B construction detail with concrete connection detail

Assembly on a concrete upstand

Accessories for the LAMILUX Continuous Rooflight B Passivhaus

LAMILUX Continuous Rooflight B Passivhaus with fall-through grille for fall protection

Permanently fall-through protected as certified by the BG, suitable for clear widths from 1.00 to 4.00 m, and can be flexibly mounted on curved sheet metal

Fall protection grille
LAMILUX Continuous Rooflight B Passivhaus with fall-through grille for fall protection

Permanently fall-through protected as certified by the BG, suitable for clear widths from 1.00 to 4.00 m, and can be flexibly mounted on curved sheet metal

DIN 18230-1

Fire Protection in Industrial Construction

This standard specifies requirements for structural fire protection in industrial buildings to effectively limit the spread of fire and damage. The LAMILUX Continuous Rooflight meets these requirements thanks to the proven fusibility of its glazing: In the event of a fire, this specifically reduces the fire load in the roof area and ensures that smoke compartments remain clearly delineated.

DIN 18234-3

Fire Resistance of Roofs

The standard defines the requirements for roof structures to prevent the spread of fire within the roof area. The LAMILUX Continuous Rooflight B Passivhaus meets these requirements and offers proven fire resistance. This keeps the fire contained to a specific area while protecting escape and rescue routes.

Continuous Rooflight B Passivhaus for thermal insulation

The LAMILUX Continuous Rooflight B Passivhaus combines architectural freedom with high energy efficiency. It brings natural daylight into buildings over a large area, permanently reduces operating costs, and noticeably improves the indoor climate. This Passivhaus-certified Continuous Rooflight suits industrial buildings, large halls and custom structures where resource conservation and comfort go hand in hand.

Documents and downloads

Continuous Rooflight B Passivhaus

Passivhaus certificate

en-us-gb

Intended use of daylight systems

Instructions for use